说明可以采取以下设置,计算和工艺应用相关的参数:- 通过p3900 > 0 退出快速调试- 写入 p0340 = 1, 3, 5p0500 = 0 时设置以下参数触发计算:-p1574 = 10 V- p1750.2 = 0- p1802 = 4(RZM/FLB 无过调制)(PM240: p1802 =0, PM260: p1802 = 2)- p1803 = 106 % (PM260: p1803 = 103 %)p0500 = 1时设置以下参数触发计算:- p1574 = 2 V- p1750.2 = 0- p1802 = 4(RZM/FLB无过调制)(PM240: p1802 = 0)- p1803 = 106 % (PM260: p1803 = 103 %)p0500= 2 时设置以下参数触发计算:- p1574 = 2 V(他励同步电机: 4 V)- p1750.2 = 1- p1802 =4(RZM/FLB 无过调制)(PM240: p1802 = 0)- p1803 = 106 % (PM260: p1803 =103 %)p0500 = 3 时设置以下参数触发计算:- p1574 = 2 V- p1750.2 = 1- p1802 =4(RZM/FLB 无过调制)(PM240: p1802 = 0)- p1803 = 106 % (PM260: p1803 =103 %)p0500 = 5 时:- p1574、p1750.2、p1802、p1803 同 p0500 = 0- p1610 =80 %,p1611 = 80 %(中至高启动转矩)- p1310 = 80 %,p1311 = 30%任何情况下都会开启直流分量补偿 (p3855 = 7)。p1750:p1750 的设置只与异步电机相关。p1750.2 = 1:异步电机的无编码器闭环控制生效,直至频率为零。该运行方式只适用于被动负载。它主要涉及负载在空转时不产生再生转矩、电机在脉冲禁止后自行静止的应用。p1802/ p1803:只有在未选中正弦输出滤波器(p0230 = 3, 4) 时,p1802 和 p1803 才能进行修改。